Nominal Voltage
12V DC24V DC
Start Isolation*
Yes
Amperage Operating Current
90mA (Combine)15mA (Open)
Terminal Stud Torque
60 in-lb (6.78 Nm)
Continuous Rating**
65A
Intermittent Rating***
115A (5 min)
Cable Size to Meet Ratings
6 AWG
Maximum Cable Size
1/0 AWG
Stud Material
Tinned Brass
Terminal Stud Size
1/4″ – 20 (M6)
Relay Contact Position
Combine 30 sec
13.6V DC
Open 10 sec
12.35V DC
Open 30 sec
12.75V DC
Open High
16.0V
Under Voltage Lockout****
9.5V
Weight
0.80lb (0.36 kg)
*Condition: Engine starting
Relay is open isolating batteries
Batteries are isolated to protect sensitive electronics from voltage sags and spikes
**The maximum current a switch is designed to conduct for an indefinite period.
***The maximum amount of current a switch is designed to carry for a minimum of a designated period of time.
****As a safety feature, some ACRs prevent combining into a severely discharge battery. A dual-sensing ACR will monitor the voltage on both batteries and will not connect if either battery is below the undervoltage lockout level. Use caution when combining into a battery with extremely low voltage, because this might represent a faulty battery or a problem elsewhere in the system.